Skip to main content

CCF — Other Workspaces

Yearly import of electricity and heat consumption data for any workspace beyond the primary workspaces declared in the company setup.

Schema

ColumnMandatoryDefinitionRuleTypeExample
Workspace typeYESType of workspaceSelect from dropdownsingle selectoffice
Workspace IDYESUnique code for this workspaceSpaces, - _ / | \, accented characters allowed · Uniqueness not validatedalphanumericoffice-1
CountryYESISO 3166-1 alpha-2 country of the workspaceSelect or type ISO codesingle selectIT
CityNOCity of the workspace (in English)Free textalphanumericMilan
AddressNOFull address of the workspaceStreet, City, Country in EnglishalphanumericVia Beccaria, Milan, Italy
Office typeYES if Workspace type is officeType of office spaceSelect from dropdownsingle selectown building
Surface m2YESInternal surface area in m²1 ≤ x ≤ 100,000numeric33
Occupied surface m2YES if office type is shared and accounting type is default dataPortion of the surface occupied by the company1 ≤ x ≤ 100,000numeric34532
Occupancy rate of building %YES if office type is shared and accounting type is default dataOverall occupancy rate of the space1 ≤ x ≤ 100numeric88
Upstream or downstream warehouseYES if Workspace type is warehouseWhether the warehouse serves upstream or downstream shippingsSelect from dropdownsingle selectdownstream
OwnershipYES if Workspace is warehouse or retail/showroomWhether the space is managed directly by the companySelect from dropdownsingle selectowned
Electricity accounting typeYESHow the company tracks electricity consumptionSelect from dropdownsingle selectowned data
Electricity purchased [kWh]YES if Electricity accounting type is owned dataVolume of electricity purchased in kWh1.00 ≤ x ≤ 1,000,000,000numeric40954
Renewable electricity purchased [kWh]NOVolume of renewable electricity purchased in kWh≤ Electricity purchased · 2 decimal digitsnumeric3345
Electricity self produced technology 1NOTechnology used to self-produce electricitySelect from dropdownsingle selectSolar PV
Electricity self produced technology 1 value [kWh]YES if technology 1 is selectedSelf-produced electricity for technology 1 in kWh1.00 ≤ x ≤ 1,000,000,000numeric34556
Electricity self produced technology […]NOAdditional self-production technology (repeatable)Select from dropdownsingle selectSolar PV
Electricity self produced technology […] value [kWh]YES if technology is selectedSelf-produced kWh for the additional technology1.00 ≤ x ≤ 1,000,000,000numeric34233
Heat accounting typeYESHow the company tracks heat consumptionSelect from dropdownsingle selectowned data
Heat purchased [kWh]YES if Heat accounting type is owned dataVolume of heat purchased in kWh1.00 ≤ x ≤ 1,000,000,000numeric23452
Heat self produced technology 1NOTechnology used to self-produce heatSelect from dropdownsingle selectBoiler - NG
Heat self produced technology 1 value [kWh]YES if technology 1 is selectedSelf-produced heat for technology 1 in kWh1.00 ≤ x ≤ 1,000,000,000numeric1237
Heat self produced technology […]NOAdditional heat self-production technology (repeatable)Select from dropdownsingle selectBoiler - NG
Heat self produced technology […] value [kWh]YES if technology is selectedSelf-produced kWh for the additional heat technology1.00 ≤ x ≤ 1,000,000,000numeric5430

Glossaries

WORKSPACE TYPE — 5 values: office · retail_showroom · warehouse · production_site · production_plant

OFFICE TYPE — 4 values: building-floor · own-building · shared-desk · shared-office

WAREHOUSE TYPE — 2 values: upstream · downstream

OWNERSHIP — 2 values: yes · no

ELECTRICITY/HEAT ACCOUNTING TYPE — 3 values: owned_data · default_values · not_used

ELECTRICITY SELF PRODUCED TECHNOLOGY — 4 values: Solar PV · Geothermal · Wind · Hydropower

HEAT SELF PRODUCED TECHNOLOGY — 5 values: Boiler - NG · Boiler - Oil · Boiler - Biomethane · General (direct combustion) - NG · Solar

COUNTRY ISO CODE — 249 ISO codes (see Supplier Registry — COUNTRY).

Cross-file dependencies